Compact
low profile, stainless steel throughout
Hermetically sealed,
conforming to EEC protection standard IP68
Hermetically sealed
cable entry, proof against water jet cleaning, and ingress of dirt
etc.
Automatically
accepts concentric & eccentric loading forces
Overload protection
Suitable for scales
complying ECC class III calibration rules & regulations
IML R60 / PTB
Certification, to 4000 division
Allows parallel
wiring of multi load cell applications
Capacities range
0,5 to 50 tons
EEx(i)-version
for intrinsically safe areas, optional
|
|
|
|
All data stored at nominal temperature
range. |
Capacity (= Emax) |
Ln |
t |
0,5 / 1 / 2 / 3 / 5 / 10
/ 30 / 50 |
Type / Accuracy Class according to OIML R60 |
|
|
BR / D1 |
BR / C3 |
Maximum number of verification intervals |
nmax |
|
1000 |
3000 |
Minimum verification interval |
Vmin |
|
Emax /3500 |
Emax /14000 |
Temperature coefficient sensitivity |
TKc |
%/ 10K |
<0,035 |
<0,012 |
Temperature coefficient zero |
TK0 |
%/ 10K |
<0,040 |
<0,010 |
Combined error |
Fcomb |
% |
<0,080 |
<0,018 |
Hysteresis |
Fu |
% |
<0,050 |
<0,017 |
Minimum dead load output return |
CMDLOR |
% |
<0,050 |
<0,017 |
Maximum permissible change(mpc) for creep: 0
- 30 minutes |
Cc |
% |
<0,0420 |
<0,0210 |
Maximum permissible change(mpc) for creep: 20
- 30 minutes |
Cc |
% |
<0,0090 |
<0,0045 |
Nominal sensitivity |
Cn |
mV / V |
2
|
Sensitivity tolerance |
Z |
% |
< + 1
|
Input resistance |
Re |
Ohm |
1160 ¡Ó 60
|
Output resistance |
Ra |
Ohm |
1015 ¡Ó 65
|
Insulation resistance |
Ris |
G Ohm |
> 20
|
Reference input voltage |
Usr |
V |
10
|
Maximum voltage supply |
Usmax |
V |
30
|
Maximum dead load |
UDe,min |
%Emax |
0
|
Maximum load with damage |
Ll |
%Emax |
150
|
Destructive load |
Ld |
%Emax |
> 500
|
Rel.static limit concentric & eccentric |
Llq |
%Emax |
75
|
Load cell deflection at nominal load |
hn |
mm |
<0,08 ¡Ó 0,02
|
Reference temperature |
tr |
¢XC |
23
|
Nominal temperature range |
Btn |
¢XC |
- 10 ...+ 40
|
Temperature range |
Bt |
¢XC |
- 30...+ 85
|
Storage temperature range |
Bts |
¢XC |
- 50...+ 95
|
EEC protection class 9DIN 40050, EN 60529) |
Hermetically sealed, laserwelded housing IP 68
/ 1m water pressure, 1000hours, IP69K (water under high pressure) |
Material |
High-grade stainless steel 17/4 PH, polished |
EEx(i) Certification |
EEx ib IIC T6 |
Cable |
6-wir-PUR-cable Ø 6,5 mm, screened |
|
|
|
|