MICROWAVE SENSOR

 
The Hydro-Mix V microwave sensor uses the unique Hydronix digital measuring techniques to provide a greater accuracy of measurement over a wider range of moisture contents than any other sensor on the market.
Designed for rugged wear in all types of mixer, the Hydro-Mix V sensor with integral signal processing provides a linear output (both analogue and serial) that may now connect directly to any control system or interface in 'compatibility' mode with Hydronix control and interface equipment.

HydroMix V MICROWAVE SENSOR

Features
Specification

 

Measuring in the mixer
Sensor can be remotely configured
Sensor response may be adjusted
Autotrack - mix ok?
Graphic display
Accuracy of measurement up to 0.1%
Synchronized readings
Sensor outputs is selectable
Linear unscaled output is provided for calibration
Temperature measurement
Ceramic faceplate is used to slow down the wearing





SIZE
Diameter 108mm, Length 140mm.
CONSTRUCTION
Body: Stainless Steel (AISI304) End Cap: Stainless Steel (AISI304) Faceplate: Syalon ceramic
RANGE OF MOISTURE
Sensor will measure up to saturation of material. Usually around 15% in standard concreate mixes, higher in lightweight aggregates.
PENETRATION
Approximately 75-100mm dependent on material.
SUPPLY VOLTAGE
Wide range power supply input 15 - 30Vdc (recommended nominal supply voltage 24Vdc). Requires approximately 140mA at +15Vdc, 100mA at 24Vdc.
TEMPERATURE
Operating temperature 0-60 degrees C. N.B. The sensor will not measure moisture in frozen materials.
ANALOGUE OUTPUT
Configurable 0-20mA or 4-20mA current loop source. For 0-10Vdc output an external 500R load resistor should be connected across the output at the control system end.
DISCREATE INPUTS
To synchronise data collection and masking to an external trigger (ie paddle proximity indicator) or to select between moisture and temperature analogue output.
REFRESH RATE
Outputs are updated approximately 25 times per second.
DIGITAL (SERIAL) COMMUNICATIONS
Opto-isolated RS 485 2 wire port.
GROUNDING
Sensor body is connected to cable shield. An external earth lug is also provided. Ensure equipotential bonding of all exposed metalwork. In areas with high risk of lightning strike, correct and adequate protection is essential.