Main Supply |
110V / 220V AC
±10%, 50/60Hz |
Power Consumption |
18VA |
Line Filter |
Built-in |
Operating Temperature |
-10ºC to 50ºC (14ºF
to 122ºF) |
Relative Humidity |
90%, non-condensing |
Load Cell Type |
All strain gauge type |
Load Cell Supply |
10V DC, 120mA (4x350 £[ load cell) |
Input Sensitivity |
0.5 µ V/D to 300 µ V/D
(2 steps) |
Zero Adjustment |
Range from 0.05mV to 15mV |
Temperature Coefficient |
10 ppm/ºC of F. S. D. |
Non-linearity |
0.005% of F. S. D. |
Conversion Rate |
120 times / sec |
Scale Range |
500 to 100,000 |
Step Width |
1, 2, 5, 10, 20, or 50 |
Maximum Display Resolution |
10,000 divisions |
Display |
- 6 digits 13mm Fluorescent tube (Green)
- 6digits 9mm LED display (Red)
|
BCD Output Rate |
15, 50 or 100 times / second |
Output Capacity |
Open collector output (max. 80V,
0.3A) |
Optional Relay Output Board |
Voltage free contact (max. 220V,
1A) |
Input / Output Control Point |
6 nos / 12 nos |
PLC Sequence |
5 sets (programmable) |
Standard RS232 Port or RS485 Port |
Bi-directional, 2400, 4800 , 9600
or 19200 bps selectable, 7 data bit, even parity, 1 stop bit |
Supplied Accessories |
Instruction manual, Load cell connector,
Power cable, Fuse |
Dimension |
198mm (W) x 96mm (H) x 200mm (L) |
Weight |
2 kg approx. |
|
|
|
|