Main supply |
110V, 220V, ¡Ó 10% AC, 50/60 Hz |
Power consumption |
18VA |
Line filter |
Built-in |
Operating temperature |
-10¢X C to 50¢X C (14¢X F to 122¢XF) |
Relative humidity |
90%, non-condensing |
Load cell type |
All strain gauge type |
Load cell type |
10VDC, 120mA (4x350 ohms load cell) |
Input sensitivity |
0.5£g V/D to 300uV/D (2 steps) |
Zero point adjustment |
Range from 0.05mV to 15mV |
Span stability |
¡Ó(0.4 £g V + 0.005% of the initial zero offset voltage)/K |
Non-linearity |
Within 0.005% of full scale |
Conversion rate |
120 times / second |
Scale range |
500 to 100,000 |
Number of ingredients |
15 |
Input/Output control point |
6 nos. / 12 nos. |
Output capacity |
open collector, 80VDC 0.3A (Max.) |
Optional relay output board |
Voltage free contact (Max. 220V 1A) |
Built-in RS232/RS485 port |
2400, 4800, 9600 or 19200 baud selectable 7 data bit, even
parity, 1 stop bit |
Supplied accessories |
Instruction manual, power cord, Load cell connector, Fuse |
Optional accessories |
BCD, 0~5V or 0~20mA or 4~20mA analog output |
Dimensions |
198mm (W) x 96mm (H) x 200mm (L) |
Weight |
2kg approx. |