Mains Supply |
110V or 220V AC selectable, 50/60Hz |
Power Consumption |
9VA |
Line Filter |
Built -in |
Operating Temperature |
-10˘XC to 50˘XC (14˘XF to 122˘XF) |
Relative Humidity |
90%, non-condensing |
Load Cell Type |
All strain gauge type |
Load Cell Supply |
10V DC, 150mA max |
Input Sensitivity |
0.5mV/V to 2mV/V |
Zero Point Adjustment |
Range from 0.05mV to 15mV |
Temperature Coefficient |
Less than (0.0008% of reading + 0.3 digitals)/˘XC |
Non-Linearity |
Within 0.0067% of full scale |
Conversion Rate |
200 times/seconds |
Scale Range |
500 to 100,000 |
Step Width |
1,2,5,10,20 or 50 |
Maximum Display Resolution |
15,000 divisions |
Number of Ingredients |
4 |
Built in RS232/RS485 Port |
2400, 4800, 9600 or 19200 baud selectable, 7 data bit, Even
parity, 1 stop bit |
Supplied accessories |
Instruction manual |
Output capacity |
Open collector max 80V 0.3A |
Dimensions |
96mm (W) x 48mm (H) x 162mm (L) |
(Specifications subject to change without notice)
Option |
* 0-5V, 4-20mA or 0-20mA analog output or BCD output
(select only one) |
* TP 150 serial printer |
|
|
|
|